Infoblox 7.x DNS Security Technical Implementation Guide
Rules, Groups, and Values defined within the XCCDF Benchmark
-
SRG-APP-000185-DNS-000021
<GroupDescription></GroupDescription>Group -
The Infoblox system must be configured to employ strong authenticators in the establishment of nonlocal maintenance and diagnostic sessions.
<VulnDiscussion>If maintenance tools are used by unauthorized personnel, they may accidentally or intentionally damage or compromise the syst...Rule Medium Severity -
SRG-APP-000213-DNS-000024
<GroupDescription></GroupDescription>Group -
The Infoblox system must be configured to provide additional data origin artifacts along with the authoritative data the system returns in response to external name/address resolution queries.
<VulnDiscussion>The underlying feature in the major threat associated with DNS query/response (i.e., forged response or response failure) is ...Rule Medium Severity -
SRG-APP-000214-DNS-000025
<GroupDescription></GroupDescription>Group -
A DNS server implementation must provide the means to indicate the security status of child zones.
<VulnDiscussion>If name server replies are invalid or cannot be validated, many networking functions and communication would be adversely aff...Rule Medium Severity -
SRG-APP-000214-DNS-000079
<GroupDescription></GroupDescription>Group -
The Key Signing Key (KSK) rollover interval must be configured to no less than one year.
<VulnDiscussion>The DNS root key is a cryptographic public-private key pair used for DNSSEC signing of the DNS root zone records. The root zo...Rule Medium Severity -
SRG-APP-000215-DNS-000003
<GroupDescription></GroupDescription>Group -
The Infoblox system implementation must enforce approved authorizations for controlling the flow of information between DNS servers and between DNS servers and DNS clients based on DNSSEC policies.
<VulnDiscussion>A mechanism to detect and prevent unauthorized communication flow must be configured or provided as part of the system design...Rule Medium Severity