Skip to content

Guide to the Secure Configuration of Oracle Linux 7

Rules, Groups, and Values defined within the XCCDF Benchmark

  • Enable the NTP Daemon

    The ntpd service can be enabled with the following command:
    $ sudo systemctl enable ntpd.service
    Rule Medium Severity
  • SSH Max Keep Alive Count

    Specify the maximum number of idle message counts before session is terminated.
    Value
  • Remove NIS Client

    The Network Information Service (NIS), formerly known as Yellow Pages, is a client-server directory service protocol used to distribute system conf...
    Rule Unknown Severity
  • Configure Time Service Maxpoll Interval

    The <code>maxpoll</code> should be configured to <xccdf-1.2:sub idref="xccdf_org.ssgproject.content_value_var_time_service_set_maxpoll" use="legacy...
    Rule Medium Severity
  • Specify Additional Remote NTP Servers

    Depending on specific functional requirements of a concrete production environment, the Oracle Linux 7 system can be configured to utilize the serv...
    Rule Medium Severity
  • Specify a Remote NTP Server

    Depending on specific functional requirements of a concrete production environment, the Oracle Linux 7 system can be configured to utilize the serv...
    Rule Medium Severity
  • Ensure Chrony is only configured with the server directive

    Check that Chrony only has time sources configured with the server directive.
    Rule Medium Severity
  • A remote time server for Chrony is configured

    <code>Chrony</code> is a daemon which implements the Network Time Protocol (NTP). It is designed to synchronize system clocks across a variety of s...
    Rule Medium Severity
  • Specify Additional Remote NTP Servers

    Additional NTP servers can be specified for time synchronization in the file <code>/etc/ntp.conf</code>. To do so, add additional lines of the fol...
    Rule Unknown Severity
  • Specify a Remote NTP Server

    To specify a remote NTP server for time synchronization, edit the file <code>/etc/ntp.conf</code>. Add or correct the following lines, substituting...
    Rule Medium Severity

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.

Capacity