Forescout Network Access Control Security Technical Implementation Guide
Rules, Groups, and Values defined within the XCCDF Benchmark
-
SRG-NET-000525-NAC-002430
<GroupDescription></GroupDescription>Group -
Forescout that stores device keys must have a key management process that is FIPS-approved and protected by Advanced Encryption Standard (AES) block cipher algorithms. This is required for compliance with C2C Step 1.
<VulnDiscussion>The NAC that stores secret or private keys must use FIPS-approved key management technology and processes in the production a...Rule High Severity -
SRG-NET-000320-NAC-001200
<GroupDescription></GroupDescription>Group -
Communications between Forescout endpoint agent and the switch must transmit access authorization information via a protected path using a cryptographic mechanism. This is required for compliance with C2C Step 1.
<VulnDiscussion>Forescout solution assesses the compliance posture of each client and returns an access decision based on configured security...Rule Medium Severity -
SRG-NET-000492-NAC-002110
<GroupDescription></GroupDescription>Group -
Forescout must generate a log record when the client machine fails policy assessment because required security software is missing or has been deleted. This is required for compliance with C2C Step 1.
<VulnDiscussion>Generating log records with regard to modules and policies is an important part of maintaining proper cyber hygiene. Keeping ...Rule Medium Severity -
SRG-NET-000336-NAC-001390
<GroupDescription></GroupDescription>Group -
Forescout must be configured with a secondary log server, in case the primary log is unreachable. This is required for compliance with C2C Step 1.
<VulnDiscussion>It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required....Rule Medium Severity -
SRG-NET-000512-NAC-002310
<GroupDescription></GroupDescription>Group -
Forescout must deny network connection for endpoints that cannot be authenticated using an approved method. This is required for compliance with C2C Step 4.
<VulnDiscussion>Without identifying devices, unidentified or unknown devices may be introduced, thereby facilitating malicious activity. Iden...Rule Medium Severity
Node 2