Fortinet FortiGate Firewall NDM Security Technical Implementation Guide
Rules, Groups, and Values defined within the XCCDF Benchmark
-
SRG-APP-000357-NDM-000293
<GroupDescription></GroupDescription>Group -
The FortiGate device must allocate audit record storage capacity in accordance with organization-defined audit record storage requirements.
<VulnDiscussion>To ensure network devices have a sufficient storage capacity in which to write the audit logs, they need to be able to alloca...Rule Medium Severity -
SRG-APP-000515-NDM-000325
<GroupDescription></GroupDescription>Group -
The FortiGate device must off-load audit records on to a different system or media than the system being audited.
<VulnDiscussion>Information stored in one location is vulnerable to accidental or incidental deletion or alteration. Offloading is a common ...Rule Medium Severity -
SRG-APP-000360-NDM-000295
<GroupDescription></GroupDescription>Group -
The FortiGate device must generate an immediate real-time alert of all audit failure events requiring real-time alerts.
<VulnDiscussion>It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required....Rule Medium Severity -
SRG-APP-000373-NDM-000298
<GroupDescription></GroupDescription>Group -
The FortiGate device must synchronize internal information system clocks using redundant authoritative time sources.
<VulnDiscussion>The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run ...Rule Medium Severity -
SRG-APP-000374-NDM-000299
<GroupDescription></GroupDescription>Group -
The FortiGate device must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).
<VulnDiscussion>If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analys...Rule Medium Severity