Skip to content

z/OS BMC CONTROL-O for RACF Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • BMC CONTROL-O resources must be properly defined and protected.

    BMC CONTROL-O can run with sensitive system privileges, and potentially can circumvent system controls. Failure to properly control access to product resources could result in the compromise of the...
    Rule Medium Severity
  • SRG-OS-000104

    Group
  • BMC CONTROL-O Started Task name is not properly identified / defined to the system ACP.

    BMC CONTROL-O requires a started task that will be restricted to certain resources, datasets and other system functions. By defining the started task as a userid to the system ACP, It allows the AC...
    Rule Medium Severity
  • SRG-OS-000104

    Group
  • BMC CONTROL-O configuration/parameter values are not specified properly.

    BMC CONTROL-O configuration/parameters control the security and operational characteristics of products. If these parameter values are improperly specified, security and operational controls may b...
    Rule Medium Severity
  • BMC CONTROL-O Started task(s) must be properly defined to the STARTED resource class for RACF.

    Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of pr...
    Rule Medium Severity

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.

Capacity