Skip to content

Palo Alto Networks NDM Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • SRG-APP-000516-NDM-000317

    Group
  • The Palo Alto Networks security platform must not use Password Profiles.

    Password profiles override settings made in the Minimum Password Complexity window. If Password Profiles are used they can bypass password complexity requirements.
    Rule Medium Severity
  • SRG-APP-000516-NDM-000317

    Group
  • SRG-APP-000516-NDM-000334

    Group
  • The Palo Alto Networks security platform must generate an audit log record when the Data Plane CPU utilization is 100%.

    Auditing and logging are key components of any security architecture. Logging the actions of specific events provides a means to investigate an attack; to recognize resource utilization or capacity...
    Rule Medium Severity
  • SRG-APP-000395-NDM-000310

    Group
  • SRG-APP-000148-NDM-000346

    Group
  • The Palo Alto Networks security platform must enforce the limit of three consecutive invalid logon attempts.

    By limiting the number of failed logon attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute-forcing, is reduced.
    Rule Medium Severity
  • The Palo Alto Networks security platform must display the Standard Mandatory DoD Notice and Consent Banner before granting access to the device.

    Display of the DoD-approved use notification before granting access to the network device ensures privacy and security notification verbiage used is consistent with applicable federal laws, Executi...
    Rule Low Severity
  • The Palo Alto Networks security platform must generate audit records when successful/unsuccessful attempts to access privileges occur.

    Without generating audit records that are specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an in...
    Rule Medium Severity