Microsoft Windows Server 2022 Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • SRG-OS-000480-GPOS-00227

    Group
  • Windows Server 2022 session security for NTLM SSP-based servers must be configured to require NTLMv2 session security and 128-bit encryption.

    Microsoft has implemented a variety of security support providers for use with Remote Procedure Call (RPC) sessions. All of the options must be enabled to ensure the maximum security level.
    Rule Medium Severity
  • SRG-OS-000067-GPOS-00035

    Group
  • SRG-OS-000478-GPOS-00223

    Group
  • Windows Server 2022 must be configured to use FIPS-compliant algorithms for encryption, hashing, and signing.

    This setting ensures the system uses algorithms that are FIPS-compliant for encryption, hashing, and signing. FIPS-compliant algorithms meet specific standards established by the U.S. Government an...
    Rule Medium Severity
  • SRG-OS-000480-GPOS-00227

    Group
  • SRG-OS-000373-GPOS-00156

    Group
  • Windows Server 2022 User Account Control (UAC) approval mode for the built-in Administrator must be enabled.

    UAC is a security mechanism for limiting the elevation of privileges, including administrative accounts, unless authorized. This setting configures the built-in Administrator account so that it run...
    Rule Medium Severity
  • SRG-OS-000134-GPOS-00068

    Group
  • Windows Server 2022 UIAccess applications must not be allowed to prompt for elevation without using the secure desktop.

    User Account Control (UAC) is a security mechanism for limiting the elevation of privileges, including administrative accounts, unless authorized. This setting prevents User Interface Accessibility...
    Rule Medium Severity