Skip to content

Juniper SRX Services Gateway NDM Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • For local accounts using password authentication (i.e., the root account and the account of last resort), the Juniper SRX Services Gateway must enforce password complexity by requiring at least one uppercase character be used.

    Use of a complex passwords helps to increase the time and resources required to compromise the password. Password complexity, or strength, is a measure of the effectiveness of a password in resisti...
    Rule Medium Severity
  • SRG-APP-000167-NDM-000255

    Group
  • For local accounts using password authentication (i.e., the root account and the account of last resort), the Juniper SRX Services Gateway must enforce password complexity by requiring at least one lowercase character be used.

    Use of a complex password helps to increase the time and resources required to compromise the password. Password complexity, or strength, is a measure of the effectiveness of a password in resistin...
    Rule Medium Severity
  • SRG-APP-000168-NDM-000256

    Group
  • For local accounts using password authentication (i.e., the root account and the account of last resort), the Juniper SRX Services Gateway must enforce password complexity by requiring at least one numeric character be used.

    Use of a complex password helps to increase the time and resources required to compromise the password. Password complexity, or strength, is a measure of the effectiveness of a password in resistin...
    Rule Medium Severity
  • SRG-APP-000169-NDM-000257

    Group
  • SRG-APP-000172-NDM-000259

    Group
  • The Juniper SRX Services Gateway must use the SHA256 or later protocol for password authentication for local accounts using password authentication (i.e., the root account and the account of last resort).

    Passwords must be protected at all times, and encryption is the standard method for protecting passwords. If passwords are not encrypted, they can be plainly read (i.e., clear text) and easily comp...
    Rule High Severity
  • SRG-APP-000411-NDM-000330

    Group
  • SRG-APP-000411-NDM-000330

    Group