Skip to content

HYCU Protege Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • SRG-APP-000029-NDM-000211

    Group
  • The HYCU virtual appliance must automatically audit account removal actions.

    Account management, as a whole, ensures access to the network device is being controlled in a secure manner by granting access to only authorized personnel. Auditing account removal actions will su...
    Rule Medium Severity
  • SRG-APP-000175-NDM-000262

    Group
  • The HYCU virtual appliance must be configured to use DOD-approved online certificate status protocol (OCSP) responders or certificate revocation lists (CRLs) to validate certificates used for PKI-based authentication.

    Once issued by a DOD certificate authority (CA), public key infrastructure (PKI) certificates are typically valid for three years or shorter within the DOD. However, there are many reasons a certif...
    Rule High Severity
  • SRG-APP-000516-NDM-000336

    Group
  • SRG-APP-000149-NDM-000247

    Group
  • The HYCU virtual appliance must be configured to use DOD PKI as multifactor authentication (MFA) for interactive logins.

    MFA is when two or more factors are used to confirm the identity of an individual who is requesting access to digital information resources. Valid factors include something the individual knows (e....
    Rule High Severity
  • SRG-APP-000091-NDM-000223

    Group
  • SRG-APP-000495-NDM-000318

    Group
  • The HYCU virtual appliance must generate audit records when successful/unsuccessful attempts to modify administrator privileges occur.

    Without generating audit records that are specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an in...
    Rule Medium Severity

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.

Capacity