Skip to content

Unified Endpoint Management Server Security Requirements Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • The UEM server must be configured to write to the server event log when invalid inputs are received.

    <VulnDiscussion>A common vulnerability of applications is unpredictable behavior when invalid inputs are received. This requirement guards ag...
    Rule Medium Severity
  • SRG-APP-000454

    <GroupDescription></GroupDescription>
    Group
  • The UEM server must remove old software components after updated versions have been installed.

    &lt;VulnDiscussion&gt;Previous versions of software components that are not removed from the information system after updates have been installed m...
    Rule Medium Severity
  • SRG-APP-000456

    <GroupDescription></GroupDescription>
    Group
  • The UEM server must be maintained at a supported version.

    &lt;VulnDiscussion&gt;The UEM vendor maintains specific product versions for a specific period of time. MDM/EMM server versions no longer supported...
    Rule High Severity
  • SRG-APP-000472

    <GroupDescription></GroupDescription>
    Group
  • The UEM server must be configured with the periodicity of the following commands to the agent of six hours or less: - query connectivity status - query the current version of the managed device firmware/software - query the current version of installed mobile applications - read audit logs kept by the managed device.

    &lt;VulnDiscussion&gt;Without verification, security functions may not operate correctly and this failure may go unnoticed. Security function is ...
    Rule Medium Severity
  • SRG-APP-000473

    <GroupDescription></GroupDescription>
    Group
  • The UEM server must run a suite of self-tests during initial start-up (power on) to demonstrate correct operation of the server.

    &lt;VulnDiscussion&gt;Without verification, security functions may not operate correctly and this failure may go unnoticed. Security function is ...
    Rule Medium Severity
  • SRG-APP-000474

    <GroupDescription></GroupDescription>
    Group

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.

Capacity
Modules