CCI-001606
Identify potential accessibility problems to outline explicit mitigation actions.
The LAN hardware supporting VVoIP services must provide redundancy to support command and control (C2) assured services and Fire and Emergency Services (FES) communications.
1 rule found Severity: Medium

The LAN hardware supporting VVoIP services must provide physically diverse pathways for redundant links supporting command and control (C2) assured services and Fire and Emergency Services (FES) communications.
1 rule found Severity: Medium

The site's enclave boundary protection must route commercial VoIP traffic via a local Media Gateway (MG) connected to a commercial service provider using PRI, CAS, or POTS analog trunks.
1 rule found Severity: Medium

Local commercial phone service must be provided in support of continuity of operations (COOP) and Fire and Emergency Services (FES) communications.
1 rule found Severity: Medium

Critical network equipment must be redundant and in geographically diverse locations for a site supporting command and control (C2) users.
1 rule found Severity: Low

Enclaves with commercial VoIP connections must be approved by the DODIN Waiver Panel and signed by DOD CIO for a permanent alternate connection to the Internet Telephony Service Provider (ITSP).
1 rule found Severity: Medium

The Fire and Emergency Services (FES) communications over a site's telephone system must be configured to support the Department of Defense Instruction (DODI) 6055.06 telecommunication capabilities.
1 rule found Severity: Medium

The Fire and Emergency Services (F&ES) communications over a site's private telephone system must provide the originating telephone number to the emergency services answering point or call center through a transfer of Automatic Number Identification (ANI) or Automatic Location Identification (ALI) information.
1 rule found Severity: Medium

The Fire and Emergency Services (F&ES) communications over a site's private telephone system must provide a direct callback telephone number and physical location of an F&ES caller to the emergency services answering point or call center through a transfer of Automatic Number Identification (ANI) and extended Automatic Location Identification (ALI) information or access to an extended ALI database.
1 rule found Severity: Medium

The Fire and Emergency Services (F&ES) communications over a site's private telephone system must route emergency calls as a priority call in a nonblocking manner.
1 rule found Severity: Medium

Two hours of backup power must be provided for LAN Infrastructure, WAN boundary, VVoIP infrastructure, and VVoIP endpoints to support Immediate or Priority precedence C2 users.
1 rule found Severity: Medium